How to maintain a benchtop low speed centrifuge when it is not used for a long time?

Publish Time: 2025-03-06
The benchtop low speed centrifuge is a commonly used device in the laboratory to separate and precipitate different components in the sample. However, when the centrifuge is not used for a long time, it may cause performance degradation or even damage due to environmental factors or aging of components. To ensure that the benchtop low speed centrifuge can remain in good working condition after a long period of non-use, the following are some key maintenance suggestions:

1. Choice of storage environment

Dry and ventilated: The centrifuge should be stored in a dry, well-ventilated environment, avoiding moisture and high temperature. A humid environment may cause rust inside the centrifuge, while high temperature may age plastic parts.

No corrosive substances: The area where the centrifuge is stored should be away from corrosive substances, such as acids, alkalis and other chemicals to prevent these substances from corroding the metal parts of the centrifuge.

Stable placement: The centrifuge should be placed on a stable and sturdy table to avoid vibration and tipping. Make sure the centrifuge is in a horizontal state to ensure the stability of its internal mechanical structure.

2. Regular startup inspection

Low-speed operation: Even if the centrifuge has not been used for a long time, it should be started and run at a low speed regularly (such as monthly), and each operation time is about half an hour. This helps to maintain the lubrication and flexibility of the various parts of the centrifuge and prevent the parts from sticking or aging due to long-term static.

Check for abnormalities: During the startup and operation, pay attention to whether the centrifuge has abnormal noise, vibration or odor. If found, it should be stopped immediately for inspection and contact professional maintenance personnel for repair.

3. Cleaning and maintenance

External cleaning: Wipe the outer shell of the centrifuge with a soft dry cloth to remove dust and dirt. Avoid using wet cloth or corrosive cleaning agents to avoid damaging the surface coating of the centrifuge.

Internal inspection: After the centrifuge has not been used for a long time, before using it again, the lid of the centrifuge should be opened to check whether there is dust, foreign matter or moisture inside. If found, it should be cleaned in time and the inside should be blown dry with dry compressed air.

Component maintenance: For key components of the centrifuge, such as rotors, bearings, etc., regular inspection and maintenance should be carried out. If the rotor surface is worn or cracked, it should be replaced in time; the bearing part should be lubricated regularly to maintain its flexibility.

4. Precautions

Avoid collision: When carrying or moving the centrifuge, it should be handled with care to avoid collision or falling to avoid damaging the internal structure of the centrifuge.

Follow the manual: When servicing and maintaining the centrifuge, the user manual and maintenance guide of the equipment should be followed. Centrifuges of different brands and models may have different maintenance requirements, so you should read and follow the relevant instructions carefully.

Professional maintenance: If you encounter problems that the centrifuge cannot solve, such as motor failure, control system failure, etc., you should contact professional maintenance personnel for maintenance in time. Never disassemble or repair the centrifuge by yourself to avoid causing greater damage or safety hazards.

In summary, when the benchtop low speed centrifuge is not used for a long time, a series of maintenance measures need to be taken to ensure its performance and life. By choosing a suitable storage environment, regular startup inspections, cleaning and maintenance, and following the precautions, the service life of the centrifuge can be effectively extended and kept in good working condition.
×